站内搜索
|
详细信息 Product Name: Original Fluke 116 Digital HVAC Multimeter Model NO.: Fluke 116 Display: LCD Additional Measuring Item: Other Range Conversion Type: Other Maximum Scale: Other Connection Type: Other Power Source: AC and DC Theory: Other Accuracy: Other Display Mode: Digital Installation: Portable Trademark: Fluke Transport Package: Carton Specification: 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) Origin: China Product Description The Fluke 116 DMM provides the features you need to quickly troubleshoot HVAC equipmentThe Fluke 116 was specifically designed for HVAC professionals. It has everything you need to quickly troubleshoot problems with HVAC equipment and flame sensors, including a built-in thermometer to measure temperatures up to 400°C (752°F) and microamps to test flame sensors. The Fluke 116 also measures resistance, continuity, frequency, and capacitance. And the large white LED backlight makes it easy to see results even in poorly lit areas.Fluke 116 multimeters are independently tested for safe use in CAT III 600 V environments.Other useful features:Measures resistance, continuity, frequency, and capacitanceProvides Min/Max/Average to record signal fluctuationsComes with a holster with probe holders for easy storageFeatures a compact ergonomic design for one-handed operationFits into optional ToolPak™ magnetic hanger for hands-free operationCAT III 600 V safety ratedSpecificationsMaximum voltage between any terminal and earth ground600 VSafetyIEC 61010-1: Pollution Degree 2IEC 61010-2-033: CAT III 600VDisplayDigital: 6,000 counts, updates 4 per secondBar graph33 segments, updates 32 per secondOperating temperature-10°C to + 50°CStorage temperature-40°C to + 60°CBattery type9 volt Alkaline, IEC 6LR61Battery life400 hours typical, without backlightAccuracy SpecificationsDC millivoltsRange/resolution600.0 mV / 0.1 mVAccuracy±([% of reading] + [counts]): 0.5% + 2DC voltsRange/resolution6.000 V / 0.001 V60.00 V / 0.01 V600.00 V / 0.1 VAccuracy±([% of reading] + [counts]): 0.5% + 2Auto voltsRange/resolution600.0 V / 0.1 VAccuracy2.0% + 3 (DC, 45 Hz to 500 Hz)4.0% + 3 (500 Hz to 1 kHz)AC millivolts1True RMSRange/resolution600.0 mV / 0.1 mVAccuracy1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz)AC volts1True RMSRange/resolution6.000 V / 0.001 V60.00 V / 0.01 V600.0 V / 0.1 VAccuracy1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz)ContinuityRange/resolution600 Ω / 1 ΩAccuracyBeeper on < 20 Ω, off > 250 Ω detects opens or shorts of500 μs or longer.OhmsRange/resolution600.0 Ω / 0.1 Ω6.000 kΩ / 0.001 kΩ60.00 kΩ / 0.01 kΩ600.0 kΩ / 0.1 kΩ6.000 MΩ / 0.001 MΩAccuracy0.9% + 1Range/Resolution40.00 MΩ / 0.01 MΩAccuracy5% + 2Diode TestRange/resolution2.00 V / 0.001 VAccuracy0.9% + 2CapacitanceRange/resolution1000 nF / 1 nF10.00 μF / 0.01 μF100.0 μF / 0.1 μF9999 μF / 1 μF100 μF to 1000 μFAccuracy1.9% + 2Range/resolution> 1000 μFAccuracy5% + 20%Lo-Z CapacitanceRange1 nF to 500 μFAccuracy10% + 2 typicalTemperature²(Type-K thermocouple)Range/resolution-40°C to 400°C / 0.1°CAccuracy1% + 10²Range/resolution-40°F to 752°F / 0.2°FAccuracy1% + 18²AC μA true-rms (45 Hz to 500 Hz)Range/resolution600.0 μA / 0.1 μAAccuracy1.5% + 3DC μampsRange/resolution600.0 μA / 0.1 μAAccuracy1.0% + 2Hz (V or A input)²Range/resolution99.99 Hz / 0.01 Hz999.9 Hz / 0.1 Hz9.999 kHz / 0.001 Hz50.00 kHz / 0.01 HzAccuracy0.1% + 21. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.4. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
|