Login|Register|Forget password|Dashboard Back to Home|Contact|Shopcart
Unverified1st Year

Shenzhen Jotec Technology Limited  

Health & Medicine,Security & Protection

Search
新闻中心
  • 暂无新闻
产品分类
  • 暂无分类
联系方式
  • 联系人:Miss Merry
  • 电话:86-755-36890859
站内搜索
 
荣誉资质
  • 暂未上传
友情链接
  • 暂无链接
首页 > Products > Original Fluke 107 Palm-Sized Cat III Digital Multimeter
Original Fluke 107 Palm-Sized Cat III Digital Multimeter
单价 $88.00 / Piece对比
询价 暂无
浏览 198
发货 Chinaguangdongshenzhen
库存 50000Piece
过期 长期有效
更新 2020-08-08 08:46
 
详细信息
Product Name: Original Fluke 107 Palm-Sized, Cat III Digital Multimeter Model NO.: Fluke 107 Display: LCD Additional Measuring Item: Other Range Conversion Type: Other Maximum Scale: Other Connection Type: Other Power Source: AC and DC Theory: Other Accuracy: Other Display Mode: Digital Installation: Portable Trademark: Fluke Transport Package: Carton Specification: 142 mm x 69 mm x 28mm Origin: China Product Description Accuracy is available for one year after calibration, operating from 18 °C to 28 °C and relative humidity from 0% to 75%. The format of the accuracy specification is: ± ([% of reading] + [least significant digit])Precision specificationsAC voltage(40 Hz to 500 Hz)1RangeResolutionAccuracy6.000 V60.00 V600.0 V0.001 V0.01 V0.1 V1.0 % + 3DC voltage6.000 V60.00 V600.0 V0.001 V0.01 V0.1 V0.5 % + 3Exchange millivolts600.0 mV0.1 mV3.0 % + 3Diode test22.000 V0.001 V10 %Resistance(ohm)400.0 Ω4.000 kΩ40.00 kΩ400.0 kΩ4.000 MΩ40.00 MΩ0.1 Ω0.001 kΩ0.01 kΩ0.1 kΩ0.001 MΩ0.01 MΩ0.5 % + 30.5 % + 20.5 % + 20.5 % + 20.5 % + 21.5% + 3Capacitor350.00 nF500.0 nF5.000 μF50.00 μF500.0 μF1000 μF0.01 nF0.1 nF0.001 μF0.01 μF0.1 μF1 μF2 % + 52 % + 55 % + 55 % + 55 % + 55 % + 5Frequency4Hz(10 Hz - 100 kHz)50.00 Hz500.0 Hz5.000 kHz50.00 kHz100.0 kHz0.01 Hz0.1 Hz0.001 kHz0.01 kHz0.1 kHz0.1 % + 3Duty cycle41 % to 99 %0.10 %1 % typical case5AC current(40 Hz - 200 Hz)4.000 A10.00 A0.001 A0.01 A1.5 % + 3DC4.000 A10.00 A0.001 A0.01 A1.5 % + 3All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.Typically, the open circuit test voltage is 2.0 V and the short circuit current is < 0.6 mA.The parameters do not include errors due to test lead capacitance and capacitor substrate (up to 1.5 nF in the 50 nF range).All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified.Typically, the frequency is 50 Hz or 60 Hz and the duty cycle is 10% to 90%.FeaturesOverload protectionInput impedance (nominal value)Common mode rejection rationormal mode rejection ratioAC voltage600 V1>10 MΩ <100 pF2>60 dB at 50 Hz or 60 Hz at DC current−Exchange millivolts600 mV>1M, <100 pF>80 dB at 50 Hz or 60 Hz−DC voltage600 V1>10 MΩ <100 pF>100 dB at 50 Hz or 60 Hz at DC current>60 dB at 50 Hz or 60 HzUp to 6 x 105 V HzFor medium voltage (alternating current), the input impedance is approximately 1 MΩ.General technical indicatorsThe highest voltage applied to any terminal and ground600 VDisplay (LCD)6000 counts, updated three times per secondType of batteryTwo AAA batteries (NEDA 24A, IEC LR03)Battery lifeAt least 200 hoursTemperatureOperating temperature0 °C to 40 °CStorage temperature-30 °C to 60 °CRelative humidityWorking humidityNo condensation below 10 °C≤ 90 % at 10 °C to 30 °C; ≤ 75 % at 30 °C to 40 °CWorking humidity, 40 MΩ range≤ 80 % at 10 °C to 30 °C; ≤ 70 % at 30 °C to 40 °CAltitudeWorking elevation2000 mStorage altitude12,000 mTemperature coefficient0.1 X (specified accuracy) / °C (<18 °C or >28 °C)Current input fuse protection11A, 1000V fast-melting type, must use Fluke designated partsVolume (height x width x length)142 mm x 69 mm x 28 mmWeight200 gProtection levelIEC 60529: IP 40SafetyIEC 61010-1: 600 V CAT III, pollution degree 2Electromagnetic environmentIEC 61326-1: PortableElectromagnetic compatibilityApplicable only in Korea. Class A equipment (industrial broadcasting and communication equipment)1